ATTENTION ALL ELECTRICAL ENGINEERS!
WE ARE INVITING ELECTRICAL ENGINEERS & PRACTITIONERS TO AN HONEST-TO-GOODNESS TRAINING PROGRAM IN A LIFETIME. - A PROGRAM THAT WILL CATAPULT THE ENGINEER TO THE DESIRED LEVEL OF COMPETENCE, EXPERTISE & PRODUCTIVITY.
“DESIGN PRACTICES IN INDUSTRIAL ELECTRICAL SYSTEMS”
[Program for Y 2009]
Module 01: Low Voltage Systems & Applications in Industries (February 11 - 13 & July 8 - 10, 2009)
· Understanding & Application of PEC, NEC, IEEE/ANSI & IEC; Myths in the Practice; LV Systems Designing: Philippines Vs. US & European Systems; Design of Branch Circuits, Motor Circuits, Feeders & Sub-Feeders; LV/LV Transformer Circuits; Panelboards & Distribution Centers; System & Equipment Grounding in Low Voltage Systems; Fault Duties in 480/240 V Systems; Application of LV Breaker KAIC Ratings; Molded Case & Power Ckt Breakers; Setting & Coordination of LV Power Circuit Breakers, Powering I. T. Environments; System Designing for Modern Office Buildings; Single Line Diagrams; System Designing for a Manufacturing Plant.
Module 02: Medium Voltage Systems & Applications in Industries (March 11-13, & August 12 - 14, 2009)
· Applicable International Standards on MV Systems; Single Line Diagrams; Application of Load Metrics: Demand, Load & Simultaneity Factors in Power Systems Design; MV Power Cables & Terminations; Sizing & Design of Primary Substations & Power Centers; Oil-Filled & Cast Resin Power Transformers; Configuration of Distribution Systems; Myths & Applications of DD, DY, YY & YD Power Centers; Design, Sizing & Configuration of Power Plants; Power Plant Operation; Fault Duties at 4.16, 6.9, 13.8, 34.5 or 69 KV Systems; Application of Power Fuses & Circuit Breakers; Application of MV Breaker KAIC Ratings; System Grounding in MV Systems, The Philippine Grid & Distribution Codes.
Module 03: Electrical Fault Calculations & Applications In Industries (April 13–15, & September 9 - 11, 2009)
· Available Fault Duties of Philippine Systems; Impedances of Distribution Lines; Impedances in Industrial Power System; Application of Per Unit System; Three-Phase Fault Calculations; Breaker KAIC Sizing; Theory & Applications of Symmetrical Components; Symmetrical Component Networks; Through-Fault Currents; Withstand Ratings of Power Transformers; Single-Line-to-Ground Fault Calculations; SLG Faults in DY, YY, YD or DD Connected Substations; Fault Currents from Motor Contributions; Circuit Breaker Applications; Limiting Fault Currents; Design of Neutral Grounding Resistors & Reactors; Grounding Transformers; Requirements for Protective Relays/Devices; Case Histories, Fault Calculations in Power Plant Systems; Application of Power Fuses.
Module 04: Industrial Power Substation Design & Protection System (May 13–15, & October 7– 9, 2009)
· Construction of Detailed & Complete Single Line Diagrams for Substation Systems, Application of System Factors & Relations; Peculiarities & Behaviour of System Loads; Substation System Dimensioning; Application of Distribution System Configurations; System Voltage Consideration; Design & Specifications of Substation Components; The Primary Voltage Equipment; The Power Transformer; The Secondary Voltage Equipment; Fuses & Circuit Breakers in Substation Application; Application of Protective Devices; Surge Arresters; Application of Fault Calculations in Substations, Setting & Arming Up Protective Relays, Protection Coordination/Discrimination, Hands-On Testing & Simulating Protective Relays; DC & AC Schematics.
Module 05: Industrial Maintenance & Energy Management Systems (June 9 – 11 & November 11 – 13, 2009)
· Modern Maintenance Practices; System Reliability Measurements; Modern Testing Equipments; Maintenance Effectiveness Measurements; Maintenance Testings of Substations, Transformers, Power Cables, Circuit Breakers, Protective Relays & Switchgears; Designing & Setting Up Maintenance Systems for Industrial Plants; Computer-Aided Maintenance Management Systems; Latest Test Equipments & Application; Understanding Utility Bills; Identifying & Reducing Power Losses; Facts & Myths in Power Factor Correction; Power Measurements, Monitoring & Controlling Systems; Power Signature Curves & Application; Energy Management Scenarios in Industries.
For Particulars, please call: Babie/Jonna (Tel. #’s: (032) 345-4531 or (032) 343-6936; Fax #: (032) 343-6936
No comments:
Post a Comment